ABS 25 KG / 50 KG / 100 KG ABC Trolley Cartridge

MED Wheelmark Certified EN Certified

Download Download: Catalog
25KG MED Certificate: Module B | Module D
50KG MED Certificate: Module B | Module D
100KG MED Certificate: Module B | Module D

Share This On:

Description

The ABS Dry Powder trolley fire extinguisher is used to fight all common classes of fire.

Onboard a ship, weeks away from land workshops, this fire extinguisher does not require a workshop to refill or maintain. Upon discharge, the crew can simply refill the fire extinguisher with spare powder and replace the used cartridge with a new piece. A wide cylinder opening allows crew to easily check the state of the powder with the help of an adjustable spanner.

Rigorous testing ensure that the ABS Dry Powder Fire Trolley Extinguisher is suitable to the most hostile environments including onboard vessels, coastal installations, oil rigs and more.

 

What type of fire can I use this fire extinguisher for?

Class-A-Fire Class A 
Class A fires which are combustible materials such as wood, tires, furniture, plastics, etc.
Class-B-Fire Class B
Class B fires which are flammable liquids such as paint, thinner, petrol, etc.
Class-C-Fire Class C
Class C fires which are flammable gases such as LPG.*
Class-E-Fire Class E
Class E fires which are electrical fires but do not include lithium battery fires.*

*The first step of eliminating a Class C or E fire is to turn off the source by shutting off the gas or electrical supply. If there is still a fire, the fire is likely to be a class A or B fire which will be much easier to put out as compared to a C or E fire.

 

How to use a fire extinguisher?

Before you use a fire extinguisher, always ensure you have an escape route. If you have to use a fire extinguisher, do so at a safe distance. When in doubt, always choose to run. Even professional fire fighters in full fire resistant suits have been trained to never put their own lives at risk. Ensure that the fire extinguisher is located to the work area and operators are trained in the use of fire extinguishers.

Ensure that extinguisher is located close to the work area and operators are trained in the use of extinguishers.

CO2 Cartridge-Remove-Pin 1. Pull the safety pin
Cartridge-Turn-To-Open-Cartridge 2. Turn the CO2 cartridge
Aim at base of fire 3. Aim at the base of the fire
Fire Extinguisher Cartridge-Press-Pistol-Lever 4. Squeeze the Pistol lever

 

Specifications

Model141341416314166
Extinguish Agent25KG ABC50KG ABC100KG ABC
Test StandardEN1866EN1866EN1866
Propellant3LTR CO2 Cart3LTR CO2 Cart5.4LTR CO2 Cart
Discharge Distance11M11M12M
App Discharge Time25 Sec41 Sec99 Sec
Height1020mm1050mm1290mm
Width430mm450mm540mm
Depth535mm550mm700mm
App Total Weight60KG85KG120KG
Operate Temperature-30°C to 60°C-30°C to 60°C-30°C to 60°C
Working Pressure14 Bar14 Bar14 Bar
Test Pressure30 Bar30 Bar30 Bar
Fire Rating233 IV B233 IV B233 IV B
Part NoFEM-ABDC25FEM-ABDC50FEM-ABDC100

*Due to constant improvements, product specifications may differ slightly.